Operating range | 5 ft. (1.5m) to 60 ft. (18.3 m) |
Sensitivity adjustment | Potentiometer |
Power indicator | Green LED |
Detect indicator | Flashing green LED |
Mode selection switch | 3 modes, relay output, pulse (3 frequency), pulse (2 frequency) |
Pulse output | 2 wire/4 wire |
Relay output operation | Light on/dark on selection |
Relay output | Form C contacts (NO, COM, NC) |
Resistive termination | 10k Ohm across NO contact |
Power protection | Thermal fuse |
Transmitter power cycle | >300mS (for use in configuration 0 Monitored) |
Power supply | 6-40 VDC, 12-24 VAC @60Hz (configuration 0-relay only) |
Current (config. 1 and 2) | 15 mA (12 VDC, includes TX and RX wired in parallel) |
Current (config. 0) | 60 mA (relay activated) |
Operating temperature | -40F to 140F (-40C to 60C) |
Environmental | NEMA 4X |
Dimensions (L x W x H) | 3.1″ (79 mm) x 2.7″ (69 mm) x 6.6″ (168 mm) |
Weight | 0.7 lbs. |
Connections | 9 screw terminals |